Résumé du contenu

Page 1 - PSG2 500

5000187941 03 01125000187941Operator’s ManualPumpPSG2 500EN

Page 2

Safety Information PSG2 50010 wc_si000249gb.fm1.4 Service SafetyService trainingBefore servicing or maintaining

Page 3 - PSG2 500 Foreword

PSG2 500 Safety Informationwc_si000249gb.fm 111.5 LabelsA nameplate listing the model number, item number, revi-sion number, and serial number is atta

Page 4 - Foreword PSG2 500

Lifting and Transporting PSG2 50012 wc_tx001962gb.fm2 Lifting and TransportingDo not under any circumstances ins

Page 5 - Table of ContentsPSG2 500

PSG2 500 Installationwc_tx001977gb.fm 133 Installation3.1 ComponentsRef. Description Ref. Description1 Lifting handle 9 Lubricant2 Coupling 10 Shaft3

Page 6 - Table of Contents PSG2 500

Installation PSG2 50014 wc_tx001977gb.fm3.2 Preparing the Machine for First UseWhen the pump is delivered, first

Page 7

PSG2 500 Installationwc_tx001977gb.fm 15Note: See “Operating Water Level” for the water level necessary foroperation. The discharge end of the hose sh

Page 8

Installation PSG2 50016 wc_tx001977gb.fm3.5 Checks to Make Before Installation• When a grounded plug is used:Use

Page 9

PSG2 500 Installationwc_tx001977gb.fm 173.7 Connecting the Power SupplyBefore connecting leads to the terminal strip, make certain the powersupply is

Page 10 - Safety Information PSG2 500

Installation PSG2 50018 wc_tx001977gb.fm3.8 Cable AssemblyIf it is necessary to extend the cable assembly, use a

Page 11 - PSG2 500 Safety Information

PSG2 500 Operationwc_tx001992gb.fm 194 Operation4.1 Before Starting4.1.1 Make sure once again that the product is of the correct voltage andfrequency

Page 12 - 2 Lifting and Transporting

Copyright notice© Copyright 2011 by Wacker Neuson Production Americas LLCAll rights, including copying and distribution rights, are reserved.This publ

Page 13 - PSG2 500 Installation

Operation PSG2 50020 wc_tx001992gb.fmCOUNTERMEASURE: If the supply voltage is outside the tolerance,possible cau

Page 14 - Installation PSG2 500

PSG2 500 Operationwc_tx001992gb.fm 214.2 Operating Water Level Do not operate the pump below the C.W.L. (Continuous running WaterLevel) indicated bel

Page 15

Maintenance PSG2 50022 wc_tx002007gb.fm5 Maintenance5.1 Periodic Maintenance ScheduleThe table below lists basic

Page 16

PSG2 500 Maintenancewc_tx002007gb.fm 235.2 Maintenance and InspectionRegular maintenance and inspections are a necessity for continuedefficient functi

Page 17

Maintenance PSG2 50024 wc_tx002007gb.fmNote: Worn lubricant and other waste products should be disposed ofby a q

Page 18

PSG2 500 Maintenancewc_tx002007gb.fm 255.5 Disassembly and ReassemblyBefore disassembling the pump, make certain the power supply (circuitbreaker, etc

Page 19 - PSG2 500 Operation

Maintenance PSG2 50026 wc_tx002007gb.fm5.6 DisassemblyNote: To enhance serviceability, the PSG2 500 has been des

Page 20 - Operation PSG2 500

PSG2 500 Maintenancewc_tx002007gb.fm 275.7 ReassemblyThe reassembly procedure is in the reverse sequence of disassembly.5.7.1 Remove sand and other de

Page 21

Maintenance PSG2 50028 wc_tx002007gb.fm5.8 TroubleshootingBefore ordering repairs, carefully read through this m

Page 22 - Maintenance PSG2 500

PSG2 500 Technical Datawc_td000252gb.fm 296 Technical Data6.1 Standard Specifications Model: PSG2 500 BOM: 0620412Applicable liquids, consiste

Page 23 - PSG2 500 Maintenance

PSG2 500 Forewordwc_tx002041gb.fm 3ForewordSAVE THESE INSTRUCTIONS—This manual contains important instructions for the machine models below. These ins

Page 24

Technical Data PSG2 50030 wc_td000252gb.fm6.2 Operating Specifications (60 Hz)* The weight (mass) given above is

Page 25

PSG2 500 Technical Datawc_td000252gb.fm 316.3 Dimensions wc_gr004656210 (8.25)231 (9.13)174 (6.81)5 (0.20)210 (8.25)271 (10.69)228 (9)285 (11.19)mm (i

Page 26

Schematics PSG2 50032 wc_tx002022gb.fm7 Schematics If connected to a circuit protected by a fuse, use a time

Page 34

Foreword PSG2 5004 wc_tx002041gb.fm Permanent damage to the machine which will not be covered under warrantyCon

Page 41

Wacker Neuson Produktion GmbH & Co. KG, Preußenstraße 41, D-80809 München, Tel.: +49-(0)89-3 54 02-0 Fax: +49 - (0)89-3 54 02-390Wacker N

Page 42

wc_bo5000187941_03TOC.fm 5Table of ContentsPSG2 500Foreword 31 Safety Information 71.1 Signal Words Used in this Manual ...

Page 43

6 wc_bo5000187941_03TOC.fmTable of Contents PSG2 5006 Technical Data 296.1 Standard Specifications ...

Page 44

PSG2 500 Safety Informationwc_si000249gb.fm 71 Safety Information1.1 Signal Words Used in this ManualThis manual contains DANGER, WARNING, CAUTION, NO

Page 45

Safety Information PSG2 5008 wc_si000249gb.fm1.2 Machine Description and Intended UseThis machine is a submersib

Page 46

PSG2 500 Safety Informationwc_si000249gb.fm 9To protect yourself and others, make sure you thoroughly read and understand the safety information prese

Commentaires sur ces manuels

Pas de commentaire